背景: 测试过程中,发现XCC在 web inactivity session timeout 设定时间前就logout,未确定此情况是不是网络环境引起的就采用ping 命令验证
平时用得最多的就是:ping IP 或者 ping IP -t这里用加时间戳的方式ping目标IP创建ping.vbs文件,代码如下:
Dim args, flag, unsuccOut args="" otherout="" flag=0 If WScript.Arguments.count = 0 Then WScript.Echo "Usage: cscript tping.vbs [-t] [-a] [-n count] [-l size] [-f] [-i TTL] [-v TOS]" WScript.Echo " [-s count] [[-j host-list] | [-k host-list]]" WScript.Echo " [-r count] [-w timeout] destination-list" wscript.quit End if For i=0 to WScript.Arguments.count - 1 args=args & " " & WScript.Arguments(i) Next Set shell = WScript.CreateObject("WScript.Shell") Set re=New RegExp re.Pattern="^Reply|^Request|^来自|^请求" Set myping=shell.Exec("ping" & args) while Not myping.StdOut.AtEndOfStream strLine=myping.StdOut.ReadLine() 'WScript.Echo "原数据" & chr(9) & strLine r=re.Test(strLine) If r Then WScript.Echo date & " "& time & chr(9) & strLine flag=1 Else unsuccOut=unsuccOut & strLine End if Wend if flag = 0 then WScript.Echo unsuccOut end if进入 ping.vbs 文件所在目录,运行命令:
cscript ping.vbs IP -t -l 1000 -w 5000>ping.txt
参数解读: -t 一直ping -l 封包大小 -w 超时时间
Troubleshooting: 1. windows系统默认隐藏文件格式,win10 打开文件夹 –查看–选项–查看,取消勾选隐藏已知文件类型的扩展名 2. ping.vbs 放在C盘,需要以管理员身份打开命令行窗口才能运行
结果: XCC在 web inactivity session timeout 设定时间前logout是网络不好引起的,我的bug就这样没了,呜呜~~~